Frame made of aluminium profile bars connected by "Tox" connections
- All-round EPDM lip seal
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboard
Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018
Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60.
They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Serial digital video transmitter for HD video surveillance and HDcctv applications
Dual rate operation 270Mbps and 1.485Gbps
Backward compatible with HDcctv 1.0 and HDSDI (ST 292)
Integrated High Definition Visually Lossless CODEC (HDVLC™) for extended cable reach
500m over 755 (5C) CCTV coax
300m over 753 (3C) CCTV coax
150m over Cat5e/6 UTP cable
Configurable 50/75ohm cable driver output, for both coaxial and twisted pair cable transmission
Integrated audio embedder with support for up to 4 channels of I2S serial digital audio at 32kHz, 44.1kHz and 48kHz sample rates
Downstream ancillary data insertion
Supports both 720p and 1080p HD formats
1080p 25/29.97/30fps
720p 25/29.97/30/50/59.94/60fps
Frame made of aluminium profile bars connected by "Tox" connections
- All-round EPDM lip seal
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboards
Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018
Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120.
They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Tissu 100% COTON, arm ure toile 1/1, 230g/m2, 175 & 205cm, traite im perimpu (Schm erber 250mm)
Principales utilisations:chambres interieurs de tentes de camping